NAVAIR 17-15-50.3
TM 38-301-3
T.O. 33-1-37-3
CGTO 33-1-37-3
TABLE 2-2. STANDARD LAB RECOMMENDATION CODES - AERONAUTICAL
FOR SPECTROMETRIC ANALYSIS (Cont)
CODE
LAB REQUESTED RESAMPLES (Requires Resample)
B*
Resample ASAP, do not change oil.
C*
Resample after *** hours, do not change oil.
E*
Do not change oil. Restrict operations to local flights or reduced load operation, maintain close
surveillance and submit check samples after each flight or *** operating hours until further notice.
F*
Do not change oil. Submit resample after ground or test run. Do not operate until after receipt of
laboratory results or advice.
G*
Contamination suspected, do not change oil, resample unit and submit sample from new oil
servicing this unit..
P*
Do not fly or operate; do not change oil; submit resample ASAP.
Q*
Normal PPM reading was obtained from test cell run after complete P.E. where oil lubricated parts
were changed/removed/replaced. Monitor engine closely after installation to ensure a normal
trend before release to routine sampling.
NOTE:
* Resample (red cap) required
** Maintenance feedback required; advise laboratory of findings
*** Laboratory will specify time limit
2-10
|