NAVAIR 17-15-50.3
TM 38-301-3
T.O. 33-1-37-3
CGTO 33-1-37-3
FOR SPECTROMETRIC ANALYSIS (Cont)
CODE
GENERAL LAB RECOMMENDATIONS
A
Sample results normal, continue routine sampling.
X
Analysis results supplied to customer; no recommendation required.
Z
Previous recommendation still applies.
CODE
INSPECTION RECOMMENDATIONS (Requires Feedback)
H**
Inspect unit and advise lab of finding. Abnormal wear indicated by _____ ppm (element).
R**
Do not fly or operate; inspect filters, screens, chip detector and sumps; advise laboratory of
results.
T**
Do not fly or operate. Examine for discrepancy and advise laboratory of results and disposition. If
discrepancy found and corrected, continue operation and submit resample after *** hours of
operation. If discrepancy is not found, recommend remove component from service and send to
maintenance.
CODE
OIL CHANGE RECOMMENDATIONS (Requires Resample)
J
Contamination confirmed. Change oil, sample after *** minute run-up and after *** operating
hours.
NOTE
Contamination is defined as water, coolant, silicon, etc, and not wear-metals. Use the appropriate
recommendation codes for increasing trends or elevated wear-metal conditions.
W
Contamination suspected. Change oil; run for *** additional hours, take samples hourly. (This
code for Air Force ALC Depot use only.)
|