TM
9-2350-238-20-2
Remove two hexagon plain nuts (23),
8
two
Iockwashers
(24),
two
machine
Make sure MASTER switch is
screws (25), and 30 amp circuit breaker
OFF
before
repairing
electrical
(6)
from
angle
bracket
(10).
components. Failure to observe
Remove flasher indicator assembly light
9
this warning could result in in-
lens (26) and flasher indicator lens pre-
jury to personnel.
formed packing (27) from flasher indi-
Failure
to
remove
or
disconnect
cator
light
(28).
the batteries before removing or
Remove
LED
(29)
from
flasher
indicator
10
installing any electrical wiring
housing
(30).
harness or lead may result in in-
jury
or
damaged
equipment.
Remove two machine screws (31), two
11
Iockwashers (32), and flasher indicator
1
Disconnect and remove circuit breaker to
floodlight switch electrical lead (1) from
housing
(30)
from
angle
bracket
(10).
15 amp circuit breaker (2) and 24 volt
12
Remove two machine screws (33), two
toggle
switch
(3).
Iockwashers (34), utility outlet cover
2
Disconnect and remove level wind switch
(35), and utility outlet electrical lead (36)
from angle bracket (10).
to
circuit
breaker
electrical
lead
assembly
(4) from 24 volt toggle switch
(5)
and
30
13
Remove two hexagon plain nuts (37),
amp circuit breaker (6).
two Iockwashers (38), two hexagon
3
Remove two machine screws (7), two
capscrews (39), and cab signal light
thermal flasher (40) from angle bracket
Iockwashers (8), level wind switch instruc-
tion plate (9), and toggle switch (5) from
(10).
angle
bracket
(10).
INSPECTION/REPAIR
4
Remove two machine screws (11), two
1
Iockwashers (12), and 24 volt flasher con-
Check for broken, damaged, or missing
parts.
trol toggle switch (13) from angle bracket
(10).
If angle bracket is broken, damaged, or
2
5
If damaged, remove two drive screws (14)
missing, repair is by replacement of next
higher assembly.
and
flasher
signal
switch
identification
plate
(15)
from
angle
bracket
(10).
3
Repair is by replacement of authorized
parts (TM 9-2350-238-24P-2) which do
6
Remove two machine screws (16), two
not meet inspection criteria.
Iockwashers (17), floodlight switch iden-
tification plate (18), and toggle switch
(19)
from
angle
bracket
(10).
7
Remove four hexagon plain nuts (20), four
Iockwashers
(21),
four
machine
screws
(22), and two 15 amp circuit
breakers
(2)
from angle bracket (10).
|