TM
9-2350-238-20-2
2-71.
BRANCHED WIRING HARNESS (CONT).
MAINTENANCE
OF
INSTALLATION
Failure
to
remove
or
disconnect
the batteries before removing or
installing any electrical wiring
harness or lead may result in in-
jury
or
damaged
equipment.
1 Install
branched
wiring
harness
(1)
and
connect two branched wiring harness plug
connectors (2) to filter bypass indicator
light (3).
2 Connect
branched
wiring
harness
plug
connector
(4)
to
wiring
harness
(5).
3 Install clamps and fasteners
on
branched
wiring harness (1).
4 Connect
ground
wire
(6)
and
secure
using
washer
(7)
and
screw
(8).
5 Connect
branched
wiring
harness
electrical
connector (9)
to
differential
pressure
switch (10).
|