TM
9-2350-238-20-2
2-67. MAINTENANCE OF HYDRAULIC RESERVOIR LINES AND FITTINGS AND
HYDRAULIC RESERVOIR FILTER AND STRAINER ASSEMBLY (CONT).
REASSEMBLY/lNSTALLATION
(CONT)
Install
head
back-up
reservoir
check
17
valve (34) on reservoir outlet tube (35).
18
Install new retaining ring (36) and
hydraulic sediment strainer (37) on
reser-
voir outlet tube (35).
Install filter by-pass reservoir check valve
19
(38) on reservoir inlet tube (39).
20
Install handle
(40)
on
hydraulic
sediment
strainer (37).
21
Install bracket (41) and four thread tap-
ping screws (42) on hydraulic sediment
strainer
(37).
22
Install handle (43) and new cotter pin
(44) on handle (40).
Install strainer element (45), strainer plug
23
(46), and new reservoir filter and strainer
gasket
(47)
on
strainer
body
(48).
24
Install
strainer
body
(48)
with
assembled
parts and new reservoir filter and strainer
gasket
(47)
on
handle
(43).
Install
bar
(49),
new
Iockwasher
(50),
25
and hexagon capscrew (51) on handle
(43).