TM
9-2350-238-20-2
7 Install
hydraulic
differential
pressure
1 2 Install tube nipple (27), new preformed
switch (16), four machine screws (17),
packing (28), and plain hexagon nut
four new Iockwashers (18), and four
(29).
hexagon
plain
nuts
(19)
on
bracket
(20).
13 Install
and
connect
pressure
switch
metal
tube assembly (30) on both ends on two
8 Install new preformed packing (21) and
tube nipples (26 and 27).
tube nipple (22) on hydraulic differential
pressure switch (16).
1 4 Connect two electrical leads (31) on
9 Install
pipe
straight
adapter
(23).
hydraulic differential pressure switch
(16).
10 Install and connect pressure switch metal
tube assembly (24) on tube nipple (22)
15 Install reservoir drain ball valve (32).
and
pipe
straight
adapter
(23).
16 Install
drain
valve
quick
coupling
half
11 Install
new
preformed
packing
(25)
and
(33) on reservoir drain ball valve (32).
tube nippIe (26) on hydraulic
differential
pressure switch (16).
2-231
|