1
Remove capscrew (1), Iockwasher (2), flat
washer (3), and door lock-release lever (4)
from
access
door
(5).
2
Remove three capscrews (6), three lock-
washers (7), and stowage door handle (8)
from
access
door
(5).
3
If damaged, remove two nonmetallic seals
(9)  from  top  and
bottom
of
access
door
opening  (10).
4
If damaged, remove nonmetallic seals (11)
from
both
sides
of
access
door
opening
(10).
INSPECTION/REPAIR
1 Check
for
broken,
damaged,
or
missing
parts.
2 Repair
is
by
replacement
of
authorized
parts
(TM
9-2350-238-24P-2).
REASSEMBLY
Dry cleaning solvent is toxic and
flammable.
Wear
protective
goggles
and gloves and use only in well-
ventilated areas.
1 Remove residual adhesive from rear of ac-
cess door opening (1) using dry cleaning
solvent  (item  10,  appx  C)  and  wire  brush.
2 Apply
epoxy
resin
adhesive
(item
2,
C) to two new nonmetallic seals (2), two
new nonmetallic seals (3), and mounting
area on rear of access door opening (1).
Install new nonmetallic seals (2) and (3)
on
access
door
opening
(1).
3 Install stowage door handle (4) on access door (5) and secure with three new Iockwashers
(6)
and
three
capscrews
(7).
4 Install door lock-release lever (8), flat washer (9), new Iockwasher (10), and capscrew (11)
on access door (5).