TM
9-2350-238-20-2
2-10.
ELECTRICAL
CIRCUIT
TROUBLESHOOTING
(CONT).
Make
sure
MASTER
switch
is
OFF
before
repairing
electrical
com-
ponents. Failure to observe this warning could result in injury to
personnel.
Step 3. Disconnect lead 518 (1) from floodlight (2). Place red probe in lead 518.
Ground black probe. Set MASTER switch ON. Set FLOODLIGHTS switch
ON. If multimeter indicates about 24 volts, replace floodlight, refer to page
2-279. If multimeter indicates no voltage, repair lead 518, refer to page
2-66. Set MASTER switch OFF. Set FLOODLIGHTS switch OFF. Connect
lead.
2-50
|