Page Title: Flood light Circuit. (Cont)
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM
9-2350-238-20-2
2-10.
ELECTRICAL
CIRCUIT
TROUBLESHOOTING
(CONT).
Make
sure
MASTER
switch
is
OFF
before
repairing
electrical
com-
ponents. Failure to observe this warning could result in injury to
personnel.
Step 3. Disconnect lead 518 (1) from floodlight (2). Place red probe in lead 518.
Ground black probe. Set MASTER switch ON. Set FLOODLIGHTS switch
ON.  If  multimeter  indicates  about  24  volts,  replace  floodlight,  refer  to  page
2-279.  If  multimeter  indicates  no  voltage,  repair  lead  518,  refer  to  page
2-66. Set MASTER switch OFF. Set FLOODLIGHTS switch OFF. Connect
lead.
2-50