TM 9-2350-238-20-1
2-196. MAINTENANCE OF CRANE OPERATOR'S ENCLOSURE KIT (CONT).
INSTALLATION (CONT)
29
Support angle bracket (28) and remove
two hexagon head capscrews (29), two
lockwashers (30), and angle bracket from
bulkhead.
NOTE
Retain the circuit breaker to floodlight
switch electrical lead and 15-amp
circuit breaker for installation when
the crane operator's enclosure kit is
removed.
30
Disconnect circuit breaker to floodlight
switch electrical lead (31) from 15-amp
circuit breaker (32) and 24-volt toggle
switch (33).
Disconnect slipring to circuit breakers and
31
radio power disconnect branched wiring
harness (34) from 15-amp circuit breaker
(32) .
Remove two machine screws (35) and
32
15-amp circuit breaker (32) from angle
bracket (28).
Install 30-amp circuit breaker (36) and two
33
machine screws (35) on angle bracket
(28).
34
Connect circuit breaker to wiper motor and
defroster electrical lead assembly (37) to
30-amp circuit breaker (36) and 24-volt
toggle switch (33).
35
Connect slipring to circuit breakers and
radio power disconnect branched wiring
harness (34) to 30-amp circuit breaker
(36) .
2-1118
|