22
Install two window assembly chains (8) on
two base links (9).
23
Open vehicular window (12).
24
Peel back a portion of operator's cupola
ring cushioning pad (26) and drill a 1/2-in.
(12.70-mm) hole through its underside.
Dry cleaning solvent (SD2) is toxic
and flammable. Wear protective
goggles and gloves and use only in
well-ventilated area.
Using dry cleaning solvent, remove
25
adhesive residue from underside of
operator's cupola (16).
Clean operator's cupola ring cushioning
26
pad (26) with liquid soap and water.
Insert circuit breaker to wiper motor and
27
defroster switch electrical lead assembly
(27) through the 1/2-in. (12.70-mm) hole
and into the notch in the cupola (16).
Install loop clamp (6), machine screw (5),
28
and self-locking nut (4) on crane
operator's base assembly (7).