TM 9-2350-238-20-1
To avoid injury to personnel, do not tighten or loosen hydraulic fittings when system
q
is pressurized.
Lower the boom to stowed position before doing any maintenance on hydraulic
q
system.
Wipe up any spilled hydraulic fluid to prevent injury to personnel.
q
Install covers on open hydraulic ports, tubes, and hoses immediately after
disconnecting them to keep dirt out of hydraulic system.
NOTE
Access to suspension system hydraulic fittings is gained through the cab well.
1 Disconnect nonmetallic hose assembly (1) from tube elbow (2).
2 Loosen locknut (3) on tube elbow (2).
3 Remove tube elbow (2) with locknut (3), flat washer (4), and preformed packing (5) from lockout
c y l i n d e r (6).
4 Remove preformed packing (5), flat washer (4), and locknut (3) from tube elbow (2).
2-895
|