TM 9-2350-238-20-1
2-137. MAINTENANCE OF HYDRAULIC POWER SUPPLY LINES AND FITTINGS (AFT
SECTION) (CONT).
INSTALLATION (CONT)
Install fluid filter (15), three new Iockwashers (16), and three hexagon head capscrews (17) on
11
bulkhead.
Install new preformed packing (18) on tube nipple (19).
12
13
Install tube nipple (19) with preformed packing (18) on fluid filter (15).
Connect pump to filter metal tube assembly (20) to tube nipple (19).
14
Install new preformed packing (21) on tube nipple (22).
15
Install tube nipple (22) with preformed packing (21) on slip ring and pump assembly (13).
16
Connect pump to filter metal tube assembly (20) to tube nipple (22).
17
Install new preformed packing (23) on tube reducer (24).
18
Install tube reducer (24) with preformed packing (23) on fluid filter (15).
19
Connect filter to tee metal tube assembly (25) to tube reducer (24).
20
Connect filter to tee metal tube assembly (25) to tube tee (9).
21
Install loop clamp (26), new Iockwasher (27), and hexagon head capscrew (28) on filter to tee
22
metal tube assembly (25).