TM 9-2350-238-20-1
INSTALLATION
1
Install new locknut (1) on tee (2).
Install new preformed packing (3) and new preformed packing (4) on tube reducer (5).
2
Install tube reducer (5) with attached packings on tee (2).
3
Install new locknut (6), packing retainer (7), and new preformed packing (8) on tube tee (9).
4
Install tube tee (9) with attached parts in hull.
5
Install safety relief valve (10) on tube reducer (5) and tube tee (9), and tighten locknut (6) on
6
tube tee.
Install new preformed packing (11) on tube nipple (12).
7
Install tube nipple (12) with preformed packing (11) on slip ring and pump assembly (13).
8
Connect tee to pump metal tube assembly (14) to tube nipple (12).
9
Connect tee to pump metal tube assembly (14) to tee (2), and tighten locknut (1) on tee.
10
2-801
|