2-136. MAINTENANCE OF HYDRAULIC POWER SUPPLY LINES AND FITTINGS
(FORWARD SECTION) (CONT).
INSTALLATION (CONT)
20 Install new tube locknut (28), packing retainer (29), and new preformed packing (30) on tube
elbow (31).
21 Install tube elbow (31) with attached parts on impact wrench control (32).
22 Tighten tube locknut (28) on tube elbow (31).
23 Connect spade control valve metal tube assembly (33) to valve (27).
24 Connect spade control valve metal tube assembly (33) to tube elbow (31).
25 Install new tube locknut (34), packing retainer (35), and new preformed packing (36) on tube
elbow (37).
26 Install tube elbow (37) with attached parts on impact wrench control (32).
27 Tighten tube locknut (34) on tube elbow (37).
28 Connect flow regulator metal tube assembly (38) to tube elbow (37).
29 Connect flow regulator metal tube assembly (38) to tube nipple (5).