For reassembly of wiring harness plug connectors, refer to general maintenance, page 2-371.
1 Install master relay to bulkhead disconnect electrical lead (3) to hull through driver's
compartment.
2 Untag and connect plug connector (2) to master relay.
3 Untag and connect plug connector (1) to bulkhead disconnect to batteries.
4 Wiring harnesses and leads are secured to the hull and components with loop clamps, straps,
clips, ground screws, etc. During installation, make sure the wiring harness or lead is secure
and all hardware is tight.
2-121. MAINTENANCE OF VOLTAGE REGULATOR TO BULKHEAD DISCONNECT,
SLAVE RECEPTACLE, AND ACCESSORIES PANEL SPECIAL CABLE
ASSEMBLY; AND SLAVE RECEPTACLE AND GROUND ELECTRICAL LEAD.
d. Reassembly
a. Removal
This task covers:
e. Installation
b. Disassembly
c. Inspection/Repair
INITIAL SETUP
Materials/Parts
Electrical wire (figure D-2,
Electrical wire (figure D-2,
Electrical wire (figure D-2,
Electrical wire (figure D-2,
References
TM 9-2350-238-24P-1
Equipment Conditions
2-918 Hull access cover removed
2-840 Battery access cover open and all batteries removed
General Safety Instructions
Failure to remove or disconnect batteries before removing or installing any
electrical wiring harness or lead may result in injury or damaged equipment.
2-735