TM 9-2350-238-20-1
3 Disconnect plug connector (2) from solenoid valve.
compartment.
INSPECTION/REPAIR
1 Inspect for broken, damaged, or missing parts.
2 If damaged or missing, replace marker bands. Etch or stamp lead number on new band.
5 Repair is by replacement of authorized parts (TM 9-2350-238-24P-1).
partment.
2 Connect plug connector (2) to solenoid valve.
3 Connect shell connector (1) to prime switch.
4 Wiring harnesses and leads are secured to the hull and components with loop clamps, straps,
clips, ground screws, etc. During installation, make sure the wiring harness or lead is secure
and all hardware is tight.
2-117. MAINTENANCE OF WARNING LIGHT LOW COOLANT DETECTOR TO
BULKHEAD DISCONNECT BRANCHED WIRING HARNESS.
This task covers: a. R e m o v a l
b. Inspection/Repair
c. Installation
INITIAL SETUP
Materials/Parts
General Safety Instructions
Electrical wire (figure D-2, appx D)
References
TM 9-2350-238-24P-1
Failure to remove or disconnect
batteries before removing or installing
any electrical wiring harness or lead
Equipment Conditions
may result in injury or damaged
2-640 Batteries disconnected
equipment.
2-727
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |