Page Title: Inspection/Repair
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2350-238-20-1
2 Open air cleaner blower motor access
door (1).
Failure to remove or disconnect
batteries before removing or installing
3 Tag and disconnect shell connector (2)
from forward air cleaner centrifugal fan.
any electrical wiring harness or lead
may result in injury or damaged
4 Tag and disconnect shell connector (3)
equipment.
from line connection disconnect.
1 Wiring harnesses and leads are secured to
5 Remove disconnect to forward air cleaner
the hull and components with loop clamps,
blower motor electrical lead (4) from hull
straps, clips, ground screws, etc. Remove
through driver's compartment.
only the hardware which secures the
wiring harness or lead being removed.
4 Electrical wire is a manufactured item,
1 Inspect for broken, damaged, or missing
refer to appendix D.
parts.
5 Repair is by replacement of authorized
2 If damaged or missing, replace marker
parts (TM 9-2350-238-24P-1).
bands. Etch or stamp lead number on
new band.
3 For repair of shell connectors, refer to
general maintenance, page 2-371.