2-88. MAINTENANCE OF BULKHEAD DISCONNECT TO SWITCH PANEL BRANCHED
WIRING HARNESS (CONT).
For reassembly of wiring harness plug connector, refer to general maintenance, page 2-371.
1 Install bulkhead disconnect to switch panel branched wiring harness (1) in hull through driver's
compartment.
2 Connect seven shell connectors (2) at the following points:
a. Untag and connect two shell connectors to hydraulic pump switch (3) (clutch
operation).
b. Untag and connect shell connector to driver's indicator light (4) (clutch engaged).