2-51. MAINTENANCE OF SECONDARY FUEL FILTER (CONT).
1
Install two tube tees (1), plug (2), and two hose elbows (3) on filter cover (4).
Install fluid filter (5) on mounting bracket (6) and secure with two hexagon head capscrews (7),
2
two new Iockwashers (8), and two hexagon plain nuts (9).
Install mounting bracket (6) with fluid filter (5) and secure with one ring spacer (10), one flat
3
washer (11 ), two new Iockwashers (12), and three hexagon head capscrews (13).
Connect air heater pump nonmetallic hose
4
assembly (14).
Connect fuel filter to fuel pump nonmetallic
5
hose assembly (15).
Connect fuel supply to filter nonmetallic
6
hose assembly (16).
Connect fuel supply to filter hose
7
assembly (17) at quick-disconnect
coupling (18).
Purge and prime fuel system. Refer to
8
TM 9-2350-238-10.
Check for and repair any leaks.
9
2-478
|