TM 9-2350-238-20-1
MALE CABLE SHELL CONNECTOR
1 Strip cable insulation equal to depth of
ferrule well (1).
2 Slide shell assembly (2) over cable (3).
3 Insert cable (3) into ferrule well (1) and
crimp.
4 Place C-washer (4) over cable (3) at
crimped junction and slide shell assembly
(2) over C-washer (4) and ferrule (5).
FEMALE CABLE SHELL CONNECTOR
(WITH WASHER)
1
Strip cable insulation approximately 1/8 in.
(0.318 cm).
Slide shell assembly (1) and washer (2)
2
over cable (3).
Place cable (3) in cylindrical end of
3
terminal (4) and crimp.
Slide shell assembly (1) and washer (2)
4
over terminal (4).
FEMALE CABLE SHELL CONNECTOR
(WITH SLEEVE)
Strip cable insulation approximately 1/8 in.
1
(0.318 cm).
Slide shell assembly (1) and sleeve ( 2 )
2
over cable (3).
Place cable (3) in cylindrical end of
3
terminal (4) and crimp.
Slide shell assembly (1) and sleeve ( 2 )
4
over terminal (4).
2-377
|