TM 9-2350-238-20-1
2-15. TYPICAL MALE-TYPE PANEL MOUNTING RECEPTACLE CONNECTOR.
DISASSEMBLY
1 Drive pin contacts (1) out through rear of
insert (2) with pin extractor.
2 Unsolder cable leads (3) from solder wells
on pin contacts (1).
3 Slide insert (2) out through rear of shell
assembly (4).
REASSEMBLY
1 Strip cable insulation equal to depth of
solder wells of pin contacts (1).
2 Insert cable leads (3) into solder wells of
pin contacts (1) and solder.
3 Push insert (2) into shell assembly (4) from rear until seated. Groove (5) in insert must be
aligned with guide in shell assembly (4) to ensure proper fit.
4 Push pin contacts (1) into insert (2) from rear until seated.
2-16. TYPICAL FEMALE-TYPE PANEL MOUNTING RECEPTACLE CONNECTOR.
DISASSEMBLY
Unscrew nut (1) from shell assembly (2)
1
and slide back on cable (3).
Slide grommet (4) back on cable leads (5).
2
Drive socket contacts (6) out through front
3
of insert (7) with pin extractor.
Unsolder lead from socket contacts (6).
4
Push insert (7) out through rear of shell
5
assembly (2).
2-372
|