TM 9-2350-238-20-1
Make sure MASTER switch is OFF before repairing
electrical circuits. Failure to observe this warning
could result in injury to personnel.
Disconnect GND lead from windshield defroster disconnect. Place red
Step 7.
probe in GND lead. Ground black probe. Set MASTER switch ON. Set
windshield defroster switch ON. If multimeter indicates about 24 volts, go to
step 8. If multimeter indicates no voltage, repair GND lead between
windshield defroster and windshield defroster disconnect. Refer to page
OFF. Connect lead.
2-353
|