TM 9-2350-238-20-1
2-12. ELECTRICAL CIRCUIT TROUBLESHOOTING (CONT).
Make sure MASTER switch is OFF before repairing
electrical circuits. Failure to observe this warning
could result in injury to personnel.
Step 13. Disconnect blower solenoid ground lead. Place red probe in blower
solenoid ground lead terminal. Ground black probe. Set MASTER switch
ON. Set AIR INTAKE FAN switch ON. If multimeter indicates about 24
volts, repair blower solenoid ground lead. Refer to page 2-371. If multim-
eter indicates no voltage, notify direct support maintenance. Set MASTER
switch OFF. Set AIR INTAKE FAN switch OFF. Connect blower solenoid
ground lead.