TM 9-2350-238-20-1
Make sure MASTER switch is OFF before repairing
electrical circuits. Failure to observe this warning
could result in injury to personnel.
Step 12. Disconnect lead 344 from blower solenoid. Place red probe in lead 344.
Ground black probe. Set MASTER switch ON. Set AIR INTAKE FAN
switch ON. If multimeter indicates about 24 volts, go to step 13. If multim-
eter indicates no voltage, repair lead 344 between air intake fan and blower
solenoid. Refer to page 2-371. Set MASTER switch OFF. Set AIR lN-
TAKE FAN switch OFF. Connect lead.
2-323
|