TM 9-2350-238-20-1
Make sure MASTER switch is OFF before repairing
electrical circuits. Failure to observe this warning
could result in injury to personnel.
Step 3.
Disconnect lead 480A from fuel pump bypass solenoid valve. Place red
probe in lead 480A. Ground black probe. Set MASTER switch ON. Hold
PRIME ENGINE FUEL FILTERS/HEATER FUEL CYCLE ON AND OFF
switch ON. If multimeter indicates about 24 volts, notify direct support
maintenance. If multimeter indicates no voltage, repair lead 480A between
PRIME ENGINE FUEL FILTERS/HEATER FUEL CYCLE ON AND OFF
switch and solenoid. Refer to page 2-371. Set MASTER switch OFF.
Release PRIME ENGINE FUEL FILTERS/HEATER FUEL CYCLE ON AND
OFF switch. Connect lead.
2-299
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |