TM 9-2350-238-20-1
2-12. ELECTRICAL CIRCUIT TROUBLESHOOTING (CONT).
Step 4.
Disconnect the other lead 76 from PUMP AND HEATER IGNITER switch.
Connect multimeter to PUMP AND HEATER IGNITER switch pins. Hold
PUMP AND HEATER IGNITER switch ON. If multimeter indicates 0 ohms,
go to step 5. If multimeter indicates infinity, replace PUMP AND HEATER
IGNITER switch. Refer to page 2-582. Release PUMP AND HEATER
IGNITER switch. Connect leads.