TM 9-2350-238-20-1
Make sure MASTER switch is OFF before repairing electrical
circuits. Failure to observe this warning could result in injury to
personnel.
Disconnect lead 520 from BO-IR switch. Place red probe in lead 520.
Step 2.
Ground black probe. Set MASTER switch ON. Turn vehicular light switch
to BO DRIVE. Set BO-IR switch to IR. If multimeter indicates about 24
volts, connect lead and go to step 3. If multimeter indicates no voltage,
repair lead 520 between BO-IR switch and vehicular light switch. Refer to
Disconnect lead 514&51 5 and 520 from BO-IR switch. Place both probes in
Step 3.
switch. If multimeter indicates 0 ohms, go to step 4. If multimeter indicates
infinity, replace BO-IR switch. Refer to page 2-566. Connect leads.