TM 9-2350-238-20-1
2-12. ELECTRICAL CIRCUIT TROUBLESHOOTING (CONT).
Make sure MASTER switch is OFF before repairing electrical
circuits. Failure to observe this warning could result in injury to
personnel.
Step 1.
Remove blackout marker assembly from service headlamp. Refer to page
light switch and place in blackout drive position. Place blackout-infrared
selection switch in blackout position. Place red probe in socket. Ground
black probe. If multimeter indicates about 24 volts, replace blackout marker
assembly. If multimeter indicates no voltage, set MASTER switch OFF,
install blackout marker assembly and go to step 2.
2-248
|