TM 9-2350-238-20-1
2-12. ELECTRICAL CIRCUIT TROUBLESHOOTING (CONT).
Make sure MASTER switch is off before repairing electrical
circuits. Failure to observe this warning could result in injury to
personnel.
To access electrical accessories panel, remove left CO2 cylinder access
Step 3.
cover. Refer to page 2-923. Disconnect lead 10 from circuit breaker.
Place red probe in lead 10. Ground black probe. Set MASTER switch ON.
If multimeter indicates about 24 volts, go to step 4. If multimeter indicates
no voltage, repair lead 10. Refer to page 2-371. Set MASTER switch OFF
and connect lead.
Disconnect leads 15&25 and 10 from circuit breaker. Check continuity
Step 4.
between circuit breaker terminals. If multimeter indicates continuity, repair
lead 15&25. Refer to page 2-371. If multimeter does not indicate
continuity, replace circuit breaker. Refer to page 2-590. Connect leads.
2-238
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |