TM 9-2350-238-20-1
Place red probe in socket L (lead 90 B). Ground black probe. If multimeter
Step 5.
indicates 0 ohms, trailer receptacle is operating normally. If multimeter
does not indicate 0 ohms, repair lead 90B. Refer to page 2-371.
AH. BLACKOUT MARKER CIRCUIT.
2-235
|