2-12. ELECTRICAL CIRCUIT TROUBLESHOOTING (CONT).
Disconnect wiring harness from generator cooling fan. Place red probe in
Step 2.
plug socket A (lead 415). Ground black probe. Start engine and run at
650 rpm. Check voltage and stop engine. If multimeter indicates about 24
volts, replace generator cooling fan. Refer to page 2-552. If multimeter
does not indicate about 24 volts, go to step 3. Connect wiring harness to
generator cooling fan.
Step 3.
To access circuit breaker, remove hull transmission compartment deck
assembly. Refer to page 2-938. Disconnect leads 415 from circuit
breaker (near engine disconnect). Start engine and run at 650 rpm.
Check voltage and stop engine. If multimeter indicates about 24 volts, go
to step 4. If multimeter indicates no voltage, repair lead 415 from
generator to circuit breaker. Refer to page 2-371.