2-12. ELECTRICAL CIRCUIT TROUBLESHOOTING (CONT).
Make sure MASTER switch is OFF before repairing
electrical circuits. Failure to observe this warning
could result in injury to personnel.
Step 5.
To access bulkhead disconnect, remove driver's seat, refer to page 2-952;
and remove driver's compartment aft cowl, refer to page 2-928. Discon-
nect wiring harness at bulkhead disconnect. Place red probe in socket G
(lead 345) of plug. Ground black probe. Set MASTER and INST switches
ON. If multimeter indicates no voltage, repair lead 345 from bulkhead
disconnect to INST switch. Refer to page 2-371. If multimeter indicates
about 24 volts, repair lead 345 from bulkhead disconnect to aft air cleaner
centrifugal fan. Refer to page 2-371. Set MASTER and INST switches
OFF. Connect wiring harness at bulkhead disconnect.