TM 9-2350-238-20-1
2-12. ELECTRICAL CIRCUIT TROUBLESHOOTING (CONT).
D. INSTRUMENT SWITCH CIRCUIT.
Step 1. Disconnect both leads 27 from INST switch. Place red probe in lead 27
and ground black probe. Set MASTER switch ON. Check voltage in both
leads 27. If multimeter indicates no voltage in both leads 27, go to step 4
and connect leads 27 to INST switch. If multimeter indicates about 24
volts in one lead, connect lead 27 measuring about 24 volts to INST switch
and go to step 2. Set MASTER switch OFF.
2-110
|