TM 9-2350-238-20-1
Step 9.
Disconnect leads 459 at rectifier. Place red probe in lead 459 (pin end)
and ground black probe. If multimeter indicates no voltage, replace
rectifier. Refer to page 2-590. If multimeter indicates about 24 volts, go to
step 10. Do not connect leads 459 (at this time.)
Step 10.
Disconnect lead 459A from circuit breaker A. Disconnect lead 459B from
circuit breaker B. Connect lead 459A to circuit breaker B. Place red
probe in lead 459 (pin end) and ground black probe. If multimeter
indicates no voltage, replace rectifier. Refer to page 2-590. Disconnect
lead 459A from circuit breaker B and connect to circuit breaker A.
Connect lead 459B to circuit breaker B. Connect leads 459 at rectifier. If
problem still exists, troubleshoot instrument switch circuit. Refer to page
2-109
|