2-12. ELECTRICAL CIRCUIT TROUBLESHOOTING (CONT).
Disconnect wiring harness from master relay. Place red probe in plug
Step 3.
socket (lead 81) and ground black probe. If multimeter indicates no
voltage, go to step 4. If multimeter indicates about 24 volts, go to step 5.
Connect wiring harness to master relay.
Step 4.
To access bulkhead disconnect, remove driver's seat, refer to page 2-952;
and remove driver's compartment aft cowl, refer to page 2-928.
Disconnect wiring harness (lead 81) at bulkhead disconnect. Place red
probe on receptacle pin and ground black probe. If multimeter indicates
no voltage, repair lead 81 from bulkhead disconnect to battery. Refer to
page 2-371. If multimeter indicates about 24 volts, repair lead 81 from
bulkhead disconnect to master relay. Refer to page 2-371. Connect
wiring harness at bulkhead disconnect.