TM 9-2350-238-20-1
2-10. TOOLS AND SUPPLIES (CONT).
Table 2-2. PREVENTIVE MAINTENANCE CHECKS AND SERVICES WITH LUBRICATION
INSTRUCTIONS FOR M578 RECOVERY VEHICLE (CONT)
Item
Interval
Item To Check
Procedure
Not Fully Mission
No.
Service
Capable If:
4
Fixed Fire
(cont)
Extinguisher
System (cont)
b.
Remove CO2 cylinders (1).
c.
Weigh cylinders. Replace cylinders if they have
Any cylinders
lost more than 1 lb (0.45 kg) from their fully
have lost 1 lb
charged weight as recorded on inspection tag.
(0.45 kg) or
If charged weight is within allowable limits, re-
more of their
cord date and weight on inspection tag.
weight or any
missing cylinder.
d.
Clean and check discharge nozzles (2) and con-
trol valve (3).
e.
Pull discharge handles (4) to ensure that cables
Cable damaged
and controls operate smoothly.
or inoperative.
Install wire seals (5).
f.
Lead seal not
properly sealed.
Install CO2 cylinders (1).
g.
5
S
Fuel System
a.
Check all fuel lines and tighten connections if
Any fuel leaks,
loose or leaking, Replace damaged lines and
loose lines or
fittings.
fittings. Any
damaged lines.
b.
Replace elements in low-pressure and high-
Any damaged or
pressure fuel filters. Replace fuel filter for
Iogged fuel
driver's personnel heater. Refer to page
filter.
assembly. Refer to page 2-1056.
2-24
|