TM 9-2350-238-20-1
Table 2-2. PREVENTIVE MAINTENANCE CHECKS AND SERVICES WITH LUBRICATION
INSTRUCTIONS FOR M578 RECOVERY VEHICLE (CONT)
Not Fully Mission
Procedure
Item To Check/
Interval
Item
Capable If:
Service
No.
Auxiliary
3
Drive Clutch
(cont)
Housing
Breather, Oil
Level, and Fill
(cont)
Remove breather (1), clean with dry cleaning
b.
solvent (item 16, appx C), and install.
Check that oil level is at FULL mark on gage
c.
(2).
Remove fill plug (3) and fill with OE/HDO or
d.
OEA (item 28 or 29, appx C) as necessary.
Clean fill plug (3) with dry cleaning solvent (item
e.
16, appx C) and install.
Fixed Fire
S
4
Extinguisher
System
High pressure CO2 gas is used in this
equipment. Keep face and body clear of
release valves. Failure to observe safety
precautions may result in injury or death.
Inspect fire extinguisher cylinder data plate to
a
ensure that a hydrostatic test has been per-
formed within the past 12 years. Faulty extin-
guishers or those beyond the test time limit (12
years) shall be declared unserviceable and re-
placed.
2-23
|