TM 9-2320-386-10
Table 3-1. Troubleshooting (Contd).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
35. POWER PLANT HEATER FAILS TO START WHEN RUN-OFF-START SWITCH
IS HELD IN START POSITION
WARNING
Exhaust gases can kill. Do not operate power plant
heater in closed area occupied by personnel. Doing so
may result in injury to personnel.
CAUTION
Do not operate fuel burning personnel heater and
power plant heater at the same time. Doing so may
result in overworked electric fuel pump.
NOTE
If RUN-OFF-START switch is turned to RUN posi-
tion before red indicator light illuminates, heater will
not operate.
Step 1. Press PRESS-TO-TEST button on heater control box to check opera-
tion of circuit.
If red indicator light does not illuminate, notify unit maintenance.
Step 2. Check fuel level on fuel gauge.
Fill fuel tank if necessary.
Step 3. Check to see if power plant heater shutoff cock is closed (para. 2-4).
Open power plant heater shutoff cock.
NOTE
Select HI position if engine is cold. Select LO position
if engine is already well heated. When in HI position,
heater will automatically change to LO position when
coolant temperature exceeds 190F (88C), and auto-
matically change to HI position when coolant temper-
ature drops below 120F (49C).
36. HEATER FAILS TO CONTINUE BURNING
Check fuel level on fuel gauge.
Fill fuel tank if necessary.