Table 3-1. Troubleshooting (Contd).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
29. LONG OR CONTINUOUS PURGE CYCLE
Notify unit maintenance.
30. INSUFFICIENT AIR PRESSURE AS INDICATED BY LOW AIR PRESSURE BUZZER
OR AIR PRESSURE GAUGE
Step 1. Check to see if air reservoir drain valves are open.
If open, close air reservoir drain valves (para. 2-3).
Step 2. Check air compressor operation.
a. Start engine (para. 2-12) and allow air pressure to build.
b. Touch outlet line of air compressor.
c. If compressor outlet line is warm, proceed to step 3.
d. If compressor outlet line is cold, notify unit maintenance.
Step 3. Check air lines for loose connections or damage.
a. Tighten loose connections.
b. If air lines are damaged, notify unit maintenance.
Step 4. Deleted
Step 5. Notify unit maintenance if condition continues.
END OF TESTING!
SLAVE RECEPTACLE
31. SLAVE CABLE CONNECTED BUT ENGINE WILL NOT TURN OVER
Step 1. Check for poor receptacle connections.
Make proper connections.
Step 2. Check if slave receptacle battery cables are loose or disconnected.
If loose or disconnected, notify unit maintenance.