Click here to make tpub.com your Home Page

Page Title: FRONT WINCH
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2320-386-10
Table 3-1. Troubleshooting (Contd).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
FRONT WINCH
WARNING
Wear hand protection when handling winch cable.
Broken wires may cause injury to personnel.
22. WINCH DRUM DOES NOT TURN OR PAY OUT CABLE
Step 1. Check hydraulic reservoir oil level (para. 3-7).
If low, add oil (table 2-2).
Step 2. Check to see if drum lock knob is engaged.
Pull out drum lock knob, rotate it a quarter of a turn clockwise, and
release into a shallow slot on nut (para. 2-18).
Step 3. Check to see if cable is binding.
Free cable from drum.
Step 4. Check if winch clutch control lever is engaged.
Move winch clutch control lever to proper position (para. 2-18).
END OF TESTING!
COOLING SYSTEM
WARNING
Extreme care should be taken when removing surge
tank filler cap if temperature gauge reads above
160F (71C). Contact with steam or hot coolant
under pressure may result in injury to personnel.
23. ENGINE TEMPERATURE EXCEEDS 230F (110C)
Step 1. Check coolant level (para. 3-7).
If low, add coolant.
Step 2. Check engine oil level (para. 3-7).
If low, add oil (table 2-2).
Step 3. Check for leakage from radiator, surge tank hoses, and hose
connections.
If loose, tighten. If still leaking, notify unit maintenance.
Step 4. Check transmission oil cooler for leaks.
If leaking, notify unit maintenance.
Change 1

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business