TM 9-2320-386-10
Table 3-1. Troubleshooting (Contd).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
FRONT WINCH
WARNING
Wear hand protection when handling winch cable.
Broken wires may cause injury to personnel.
22. WINCH DRUM DOES NOT TURN OR PAY OUT CABLE
Step 1. Check hydraulic reservoir oil level (para. 3-7).
If low, add oil (table 2-2).
Step 2. Check to see if drum lock knob is engaged.
Pull out drum lock knob, rotate it a quarter of a turn clockwise, and
release into a shallow slot on nut (para. 2-18).
Step 3. Check to see if cable is binding.
Free cable from drum.
Step 4. Check if winch clutch control lever is engaged.
Move winch clutch control lever to proper position (para. 2-18).
END OF TESTING!
COOLING SYSTEM
WARNING
Extreme care should be taken when removing surge
tank filler cap if temperature gauge reads above
160F (71C). Contact with steam or hot coolant
under pressure may result in injury to personnel.
23. ENGINE TEMPERATURE EXCEEDS 230F (110C)
Step 1. Check coolant level (para. 3-7).
If low, add coolant.
Step 2. Check engine oil level (para. 3-7).
If low, add oil (table 2-2).
Step 3. Check for leakage from radiator, surge tank hoses, and hose
connections.
If loose, tighten. If still leaking, notify unit maintenance.
Step 4. Check transmission oil cooler for leaks.
If leaking, notify unit maintenance.
Change 1
|