2320-01-318-9902 EIC:B5C, VOLUME NO. 2">
|
|
TM 9-2320-360-20-2
21-4. CHEMICAL ALARM INSTALLATION
This task covers:
a. Installation
b. Follow-On Maintenance
INITIAL SETUP
Equipment Conditions
Materials/Parts
Batteries disconnected (para 7-61).
Locknuts (4) (Item 72, Appendix G)
Lockwashers (4) (Item 107, Appendix G)
Tools and Special Tools
Tool Kit, Genl Mech (Item 54, Appendix F)
a. Installation
(1) Remove four nuts (1), lockwashers (2),
washers (3), spacers (4), and screws (5)
from left front fender (6).
Discard
lockwashers.
(2) Install detector mount (7) on fender (6)
with four spacers (4), screws (5), washers
(3), new lockwashers (2), and nuts (1).
(3) Install detector (8) in mount (7).
(4) Position holder (9) on detector (8) and
tighten two nuts (10).
(5) Install power input cable (11) on detector
mount (7) with two clips (12) and screws
(13).
(6) Install electrical connector (14) and
electrical connector (15) on mount (7).
21-14
|