2320-01-318-9902 EIC:B5C, VOLUME NO. 2">
|
|
TM 9-2320-360-20-2
20-7. CTI SIGNAL GENERATOR REPLACEMENT (CONT)
b. Installation
NOTE
Do steps (1) thru (3) only when
installing
new
CTI
signal
generator.
Tabs
on
drive
key
and
speedometer
shaft
must
be
aligned with slots in transfer case
and CTI signal generator.
(1) Install two dust boots (1) on wires (2).
(2) Crimp electrical contacts (3) on wires (2).
(3) Install two wires (2) in electrical connector
(4).
(4) Install drive key
(5)
on
CTI
signal
generator (6).
(5) Install signal generator (6) on transfer
case (7).
(6) Install electrical connector (4) on electrical
connector (8) until locking tab (9) locks.
c. Follow-On Maintenance
Install speedometer adapter (para 20-6).