18-12. EXHAUST FAN REPAIR (CONT)
e. Installation
WARNING
On direct contact, uncured silicone
sealant irritates eyes.
In case of
contact, flush eyes with water and
seek medical attention.  In case of
skin contact, wipe off and flush with
water.
NOTE
Do steps (1) thru (4) only if louver
panel and/or duct hose adapter(s)
were removed.
(1) Apply silicone adhesive-sealant to sealing
surface of two duct hose adapters (1)
(2) Install two duct hose adapters (1) on cab
wall (2) with eight new rivets (3).
(3) Apply silicone adhesive-s ealant to sealing
surface of louver panel (4)
(4) Install louver panel (4) on cab wall (2) with
six screws (5).
(5) Install exhaust fan (6) and ground wire (7)
on cab floor (8) with four washers (9), new
lockwashers (10), and screws (11).
(6) Install two flexible ducts (12) on exhaust
fan (6) and two duct adapters (1) with four
new cable ties (13).
(7) Install lower backseat cushion (14) on
lower frame assembly (15) with six screws
(16) with aid of assistant.
g. Follow-On Maintenance
(1) Connect batteries (para 7-61).
(2) Operate  exhaust  fan  and  check
for
operation (TM 9-2320-360-10).
18-42 (18-43 and 18-44 deleted) (18-45 blank) Change 2