2320-01-318-9902 EIC:B5C, VOLUME NO. 2">
|
|
TM 9-2320-360-20-2
18-12. EXHAUST FAN REPAIR (CONT)
c. Cleaning/Inspection
(1) Clean interior and exterior of housings. Use any process or combination of processes which will
accomplish thorough cleaning without damage.
(2) Inspect housings for dents, crac ks, defective welds and other defects.
(3) Inspect foam strips for compression, wear, and loss of adhesion. Replace any damaged foam strips.
d. Assembly
NOTE
Do steps (1) and (2) only if foam
strips were removed.
(1) Install foam strip (1) on housing (2).
(2) Install two foam strips (3) on blower
housing (4).
(3) Install caged nut (5) on bracket (6).
NOTE
Motor assembly must be installed
with wiring harness positioned on
right side, with cage nut slot toward
the front Failure to comply will result
in improper air flow thru exhaust fan.
(4) Install motor (7) in blower housing (4) with
cushion (8), retaining strap (9), screw (10),
and washer (11).
(4.1) Install two retaining clips (11.1) on two
blower wheels (12).
CAUTION
Blower wheels must turn freely after
assembly. Failure to comply may
result in damage to equipment.
NOTE
Blower wheels must be installed in
locations marked during removal.
Failure to comply will result in
improper air flow thru exhaust fan.
(5) Install two blower wheels (12) on motor (7)
with two retaining clips (13).
(6) Install foil (14) and ground wire (15) on
blower housing (4) with three screws (16)
and new lockwasher (17).
(7) Install foil (18) on blower housing (4) with
three screws (19).
18-40 Change 2
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |