11-17. DASH MANIFOLD VALVE REPLACEMENT (CONT)
(8) Remove adapters (12 and 14) from valve (3).
(9) Remove adapter (16) from tee (17).
(10) Remove sending unit (10), bushing (18),
and elbow (19) from tee (17).
(11) Remove tee (17) from valve (3).
NOTE
Do step (12) if dash manifold valve is
being replaced or if plugs are leaking
or damaged.
(12) Remove two plugs (20) from valve (3).
b. Installation
WARNING
Pipe thread sealing compound can
burn easily, can give off harmful
vapors, and is harmful to skin and
clothing. To avoid injury or death,
keep away from open fire and use in
well-ventilated area. If pipe thread
sealing compound gets on skin or
clothing, wash immediately with soap
and water.
CAUTION
Use pipe thread sealing compound
sparingly only on pipe threads. Do
not apply compound to hose
connections. Damage to equipment
may result.
NOTE
Do steps (1) and (2) if plugs were
removed.
(1) Coat threads of two plugs (1) with pipe
thread sealing compound.
(2) Install two plugs (1) in valve (2).
(3) Coat threads of tee (3), elbow (4), bushing
(5), sending unit (6), adapter (7), adapter
(8), and adapter (9) with pipe thread
sealing compound.
(4) Install tee (3) in valve (2).
(5) Install elbow (4), bushing (5), sending unit
(6), and adapter (7) in tee (3).
(6) Install two adapters (8 and 9) in valve (2).