11-15. PRESSURE PROTECTION VALVE REPLACEMENT (CONT)
(8) Remove hose no. 2074 (9) from fitting (10).
(9) Remove two locknuts (11), screws (12),
and manifold (13) from mounting bracket
(14). Discard locknuts.
(10) Remove fitting (15) and valve (7) from
reducer (16).
(11) Remove two fittings (10 and 15) from
valve (7).
b. Installation
WARNING
Pipe thread sealing compound can
burn easily, can give off harmful
vapors, and is harmful to skin and
clothing.  To avoid injury or death,
keep away from open fire and use in
well-ventilated area.  If pipe thread
sealing compound gets on skin or
clothing, wash immediately with soap
and water.
CAUTION
Use pipe thread sealing compound
sparingly only on pipe threads.  Do
not  apply  compound  to  hose
connections.  Damage to equipment
may result.
NOTE
To install right valve, do steps (1)
thru (6). To install left valve, do steps
(7) thru (15).
(1) Coat threads of fittings (1 and 2) with pipe
thread sealing compound.
(2) Install fitting (1) on input side of valve (3).
(3) Install fitting (2) on out put side of valve (3).
(4) Install fitting (2) and valve (3) on reducer (4).
(5) Install manifold (5) on mounting bracket (6)
with two screws (7) and new locknuts (8).
(6) Install hose no. 2074 (9) on fitting (1).
11-50