7-96. VENTILATOR REPAIR (CONT)
i. Lower Plenum Installation
(1) Install electrical connector (1) on motor wire
harness (2).
(2) Install electrical connector (3) on cab rear
wire harness (4).
(3) Install new lockwasher
(5)
on
cable
assembly (6).
(4) Position cable assembly (6) thru hole in
switch plate (7).
NOTE
Ferrel insert must remain in cable
locking nut during installation. Cable
core can be rotated clockwise to keep
insert in locking nut.
(5) Install cable locking nut (8) on cable
assembly (6).
(6) Tighten nut (9) to secure cable assembly (6)
on switch plate (7).
CAUTION
Make sure that wire harness does
not interfere with any of the
moving parts inside the ventilator.
Failure to comply may result in
damage to equipment.
Bushings must be used when
installing plenum chamber to cab
roof. Failure to comply may crack
plenum chamber.
(7) Install plenum chamber (10) on cab roof
(11) with 10 screws (12) and bushings (13).
(8) Install cable knob (14) on cable assembly
(6) with new locknut (15).
j. Follow-On Maintenance.
Connect Batteries (para 7-61).