b. Installation
WARNING
Pipe thread sealing compound can
burn easily, can give off harmful
vapors, and is harmful to skin and
clothing. To avoid injury or death,
keep away from open fire and use in
well-ventilated area. If pipe thread
sealing compound gets on skin or
clothing, wash Immediately with soap
and water.
(1) Coat threads of STE-ICE turbo outlet
pressure transducer (1) and reducer (2)
with pipe thread sealing compound.
(2) Install transducer (1) and reducer (2) on
turbocharger air inlet housing (3).
(3) Install connector (4) on transducer (1).
c. Follow-On Maintenance
(1) Close engine hood (TM 9-2320-360-10).
(2) Remove wheel chocks.