17-58. SLAVE RECEPTACLE REPAIR (CONT)
b. Disassembly
(1) Loosen  four  captive  screws  (1)  and
remove cover (2) from slave receptacle
box (3).
NOTE
Tag  and  mark  positive  (+)  and
negative (-) cables and receptacle
before disassembly.
(2) Remove two screws (4) and lockwashers
(5) from cable no. 1138 (6) and cable no.
1139 (7) and receptacle (8).
Discard
(3) Remove  two  cables  (6  and  7)  and
grommets (9) from box (3).
(4) Remove four locknuts (10), washers (11),
screws  (12),  eyelet  (13),  and  cap
assembly  (14)  from  receptacle  (8).
Discard locknuts.
(5) Remove receptacle (8), gasket (15), and
insulator (16) from box (3).
c. Assembly
WARNING
Adhesive-sealant can burn easily,
can give off harmful vapors, and is
harmful to skin and clothing.  To
avoid Injury or death, keep away from
open fire and use in well ventilated
area. If adhesive-sealant gets on skin
or clothing, wash immediately with
soap and water.
(1) Coat sides of insulator (1), gasket (2), and
receptacle (3) that mount to box (4) with
silicone adhesive-sealant.
NOTE
When installing receptacle make sure
positive (+) terminal is on right side
of box.
(2) Install insulator (1), gasket (2), eyelet (5),
and receptacle (3) on box (4) with four
screws (6), washers (7), and new locknuts
(8).