4-4. TRANSMISSION (CONT)
i. Low Shift Valve Assembly (cont).
STEP
LOCATION
ITEM
ACTION
REMARKS
CLEANING (cont)
WARNING
Compressed air must not exceed 30 psi. Wear safety glasses when drying parts with compressed air.
Failure to do so could cause serious injury to eyes and possible blindness. If you hurt your eyes or if a
foreign object is blown into your eyes, seek medical attention immediately.
4
All parts
Clean
Use cleaning solvent P-D-680.
Immerse parts in solvent and
move up and down to
remove
all dirt, grease, and old
lubricant. Dry thoroughly
using clean cloths or
moisture-free compressed
air
INSPECTION
5
a
Valve body (13)
Inspect
Inspect oil passages and valve
bore for cleanliness If not
perfectly clean, reclean.
Inspect for burrs Deburr
with crocus cloth if neces-
sary Inspect valve bores
for cracks, wear, damage
and
distortion Replace if
necessary
b
Valves (17 and
Inspect
Inspect for wear, damage and
21)
distortion; if any of these
conditions are observed,
replace valve
c
Springs (16 and
Inspect
Replace if cracked, worn,
20)
distorted, broken or per-
manently set
d
All other parts
Inspect
Inspect for wear, damage,
cracks, and distortion;
replace part if any of these
conditions are observed
4-100